Technical Specification
| Model | SDP-1KW | SDP-2KW | SDP-3KW | SDP-4KW | ||
|
| Isolation mode | Low Frequency Transformer | ||||
| DC Input | Rated voltage (Vdc) | 48V | 96V | |||
| Rated currentA | 20.8A | 20.8A | 31.2A | 41.6A | ||
|
AC Input | Rated output power | 1KW | 2KW | 3KW | 4KW | |
| Output waveform | Pure Sine Wave | |||||
| Rated Voltage | 220V3% | |||||
| Phases | Single Phase | |||||
| Rated currentA | 4.5A | 9A | 13.6A | 18.1A | ||
| Frequency | 50Hz or 60Hz | |||||
| Rated output voltage range (V) | 110/120/220/230/240VAC optional | |||||
| Power FactorPF | 0.99 | |||||
| Overload Ability | 150%, 5 seconds | |||||
| Efficiency | >93% | |||||
| Waveform distortion rate (THD) | <3%Linear load | |||||
| Dynamic Response (0 to 100% load) | 5%50ms | |||||
| Display | LCD | |||||
| Running mode | Working continuously | |||||
| Electrical insulation properties | 2000Vac, 1 Minute | |||||
| Communication interface | RS485 (optional) | |||||
| Protectio Function | Protection | Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc. | ||||
| Cooling method | Fan-cooled | |||||
| Short-circuit protection | No automatic recovery, need to restart the machine | |||||
| Noise ( 1 meter) | 50dB | |||||
| Working environment | Degree of protection | IP20indoor | ||||
| Working Altitudem | 2000 | |||||
| Working temperature | -25~+55 | |||||
| relative humidity | 0~90%non-condensing | |||||
| Mechanical dimension | Depth x Width x Height | 435x605x267mm | ||||
| Model | SDP-5KW | SDP-6KW | |||||||||
|
| Isolation mode | Low Frequency Transformer | |||||||||
| DC Input | Rated voltage (Vdc) | 96V | 120V | 96V | 120V | ||||||
| Rated currentA | 52A | 42A | 62.5A | 50A | |||||||
|
AC Input | Rated output power | 5KW | 6KW | ||||||||
| Output waveform | Pure Sine Wave | ||||||||||
| Rated Voltage | 220V3% | 380VAC3% | 220V3% | 380VAC3% | |||||||
| Phases | Single Phase | 3 phase 4 wire | Single Phase | 3 phase 4 wire | |||||||
| Rated currentA | 23A | 7.6A(phase current) | 27A | 9A (phase current) | |||||||
| Frequency | 50Hz or 60Hz | ||||||||||
| Rated output voltage range (V) | 110/120/220/230/240VAC optional | ||||||||||
| Power FactorPF | 0.99 | ||||||||||
| Overload Ability | 150%, 5 seconds | ||||||||||
| Efficiency | >93% | ||||||||||
| Waveform distortion rate (THD) | <3%Linear load | ||||||||||
| Dynamic Response (0 to 100% load) | 5%50ms | ||||||||||
| Display | LCD | ||||||||||
| Running mode | Working continuously | ||||||||||
| Electrical insulation properties | 2000Vac, 1 Minute | ||||||||||
| Communication interface | RS485 (optional) | ||||||||||
| Protectio Function | Protection | Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc. | |||||||||
| Cooling method | Fan-cooled | ||||||||||
| Short-circuit protection | No automatic recovery, need to restart the machine | ||||||||||
| Noise ( 1 meter) | 50dB | ||||||||||
| Working environment | Degree of protection | IP20indoor | |||||||||
| Working Altitudem | 2000 | ||||||||||
| Working temperature | -25~+55 | ||||||||||
| relative humidity | 0~90%non-condensing | ||||||||||
| Mechanical dimension | Depth x Width x Height | 435x605x267mm | 435x635x400mm | 435x605x267mm | 435x635x400mm | ||||||
| Model | SDP-8KW | SDP-10KW | ||||||
|
| Isolation mode | Low Frequency Transformer | ||||||
| DC Input | Rated voltage (Vdc) | 120V | 192V | 192V | 240V | |||
| Rated currentA | 67A | 42A | 52A | 42A | ||||
|
AC Input | Rated output power | 8KW | 10KW | |||||
| Output waveform | Pure Sine Wave | |||||||
| Rated Voltage | 220V3% | 380VAC3% | 220V3% | 380VAC3% | ||||
| Phases | Single Phase | 3 phase 4 wire | Single Phase | 3 phase 4 wire | ||||
| Rated currentA | 36A | 12A(phase current) | 45.5A | 15A (phase current) | ||||
| Frequency | 50Hz or 60Hz | |||||||
| Rated output voltage range (V) | 110/120/220/230/240VAC optional | |||||||
| Power FactorPF | 0.99 | |||||||
| Overload Ability | 150%, 5 seconds | |||||||
| Efficiency | >93% | |||||||
| Waveform distortion rate (THD) | <3%Linear load | |||||||
| Dynamic Response (0 to 100% load) | 5%50ms | |||||||
| Display | LCD | |||||||
| Running mode | Working continuously | |||||||
| Electrical insulation properties | 2000Vac, 1 Minute | |||||||
| Communication interface | RS485 (optional) | |||||||
| Protectio Function | Protection | Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc. | ||||||
| Cooling method | Fan-cooled | |||||||
| Short-circuit protection | No automatic recovery, need to restart the machine | |||||||
| Noise ( 1 meter) | 50dB | |||||||
| Working environment | Degree of protection | IP20indoor | ||||||
| Working Altitudem | 2000 | |||||||
| Working temperature | -25~+55 | |||||||
| relative humidity | 0~90%non-condensing | |||||||
| Mechanical dimension | Depth x Width x Height | 435x635x400mm | ||||||
| Model | SDP-12KW | ||||
|
| Isolation mode | Low Frequency Transformer | |||
| DC Input | Rated voltage (Vdc) | 192V | 240V | ||
| Rated currentA | 62.5A | 50A | |||
|
AC Input | Rated output power | 12KW | |||
| Output waveform | Pure Sine Wave | ||||
| Rated Voltage | 220V3% | 380VAC3% | |||
| Phases | Single Phase | 3 phase 4 wire | |||
| Rated currentA | 55A | 18A (phase current) | |||
| Frequency | 50Hz or 60Hz | ||||
| Rated output voltage range (V) | 110/120/220/230/240VAC optional | ||||
| Power FactorPF | 0.99 | ||||
| Overload Ability | 150%, 5 seconds | ||||
| Efficiency | >93% | ||||
| Waveform distortion rate (THD) | <3%Linear load | ||||
| Dynamic Response (0 to 100% load) | 5%50ms | ||||
| Display | LCD | ||||
| Running mode | Working continuously | ||||
| Electrical insulation properties | 2000Vac, 1 Minute | ||||
| Communication interface | RS485 (optional) | ||||
| Protectio Function | Protection | Input reverse polarity, under voltage, overvoltage, output over-current, short circuit, overheating etc. | |||
| Cooling method | Fan-cooled | ||||
| Short-circuit protection | No automatic recovery, need to restart the machine | ||||
| Noise ( 1 meter) | 50dB | ||||
| Working environment | Degree of protection | IP20indoor | |||
| Working Altitudem | 2000 | ||||
| Working temperature | -25~+55 | ||||
| relative humidity | 0~90%non-condensing | ||||
| Mechanical dimension | Depthx Width x Height | 435x635x400mm | |||